-
Image
BIOMONITOR IV
A real challenge exists in the clinical world today with the volume of data generated as more patients benefit from the proven value of long-term cardiac monitoring. Valuable time and resources are spent analyzing false positive arrhythmias, leaving patients waiting for accurate answers. The intelligent technology in BIOMONITOR IV can help.
BIOMONITOR IV with SmartECG leverages artificial intelligence (AI) and advanced detection algorithms to reduce 86% of false positives across all major arrhythmias,1 alleviating the review burden and helping clinicians achieve timely and accurate diagnosis to focus on what’s most important – the patient.
Category
Product Highlights
Intelligent SmartECG
AI and advanced detection algorithms reduce 86% of false positives across all major arrhythmias1 to alleviate the review burden
Confidence from BIOTRONIK Home Monitoring
Streamlined ICM monitoring with indication-specific templates, enhanced automaticity, and intuitive reports
Clarity with PVC/PAC Diagnostics
The industry’s first to discriminate between PVCs and PACs and clearly report burden over time for personalized treatment decisions
Intelligent SmartECG
BIOMONITOR IV comes with SmartECG, an intelligent system powered by AI and advanced algorithms to reduce the number of false positive detections for Atrial Fibrillation (AF), Bradycardia, Tachycardia, and Pause.1,2 This allows you to focus on actionable events and spend more time on patient care.
- SmartECG reduces 86% of false detections across all major arrhythmias while keeping 98% of the clinically relevant episodes.3
- A recent publication by Bisignani et al. shows a meaningful workload reduction by SmartECG and up to 42% reduced time spent for episode reviews.4
- False positive AF detections may take a considerable amount of time to review. That’s why SmartECG is supported by AI for AF detection to analyze 100s of data points across each individual ECG and streamline data evaluation.
86% Reduction of All False Positive Detections3
Confidence from BIOTRONIK Home Monitoring
When it comes to system set-up, BIOMONITOR IV offers indication-specific templates, enhanced automaticity and intuitive reports for efficient access to optimized clinical data and insights. BIOTRONIK Home Monitoring® delivers on the promise of improving patient outcomes and driving operational efficiency.
- Industry-leading 98% daily transmission reliability5
- Earlier access to symptomatic episodes with On-demand transmission
- Enhanced Quick View report for easy and efficient review
New Condensed Quick View Report
Clarity with PVC/PAC Discrimination
BIOTRONIK’s BIOMONITOR IV is the industry’s first to discriminate between premature ventricular and atrial contractions (PVCs and PACs) and clearly report burden over time.6,7 BIOMONITOR IV brings a new level of intelligence to achieve accurate risk stratification based on the PVC and PAC burden and the related therapy strategy.
- High frequency of PVCs and PACs is associated with the development of AF, and with an increased risk of stroke, heart failure, and death8,9,10
- High PVC burden increases the risk of the combined endpoint of all-cause mortality, cardiovascular mortality, sudden cardiac death, or development of ischemic heart disease10
- High PVC burden is associated with 3-fold greater odds for left ventricular ejection fraction decline (after 5 years), a 48% increased risk of congestive heart failure incident (after 13 years), and a 31% increased risk of death (after 15 years)11
Long-term Diagnostic Trends Including PVC and PAC Ectopic Burden
Product Overview

Fractal iridium coating
Flexible silicone antenna
BIOvector for industry-leading signal quality
Titanium can
5 years longevity
Fractal iridium coating
Media
Downloads & Related Links
Related Products
-
ImageComplete system. Expert support.
BIOTRONIK Conduction System Pacing Solution
Working alongside physicians and listening closely to their needs, we have together developed a...
Read more -
ImageSave Time. Improve Outcomes.
BIOTRONIK Home Monitoring
Taking care of cardiac device patients can be challenging. The BIOTRONIK remote monitoring system is...
Read more -
ImagePhysiologic choices. Simplified workflows.
Amvia Sky DR-T/SR-T
The Amvia Sky pacing system gives you choices. Take advantage of a broader range of treatment...
Read more -
ImageTHE SUSPENDED RADIATION PROTECTION SYSTEM
Zero-Gravity®
The growing number and complexity of fluoroscopic procedures performed each year has increased the...
Read more -
ImageMore Life. Made Simpler.
Rivacor 7 HF-T QP/HF-T
Simplified and optimized CRT for up to 9 years1
Heart failure is tough to live with and can be...
Read more -
ImageMetallic Performance¹⁻³. Fully Resorbable*⁴
Freesolveᵀᴹ
Indicated for de novo coronary artery lesionsa
Support
Resorbable coronary scaffolds widen coronary...Read more -
ImageExtending ICD Lead Choices
Pamira
Over the years, BIOTRONIK kept on innovating and improving ICD leads, having in mind long-term...
Read more -
ImageDrug-Eluting Stent System
Synsiro® Pro
The Synsiro® Pro Sirolimus-Eluting Coronary Stent System is a drug-eluting balloon-expandable stent...
Read more -
ImageOptimised therapy. Simplified care.
Amvia Sky HF-T QP / HF-T
With a 30% non-response rate to CRT1 , therapy optimisation is essential for clinicians taking care...
Read more -
ImageMultiple solutions for lesion crossing
Carnelian® Support Catheter
A Support Microcatheter indicated for the exchange and support of guidewires into peripheral...
Read more -
ImageOne Life. Take Control with CLS
Closed Loop Stimulation
For more than 25 years, patients with pacemakers or defibrillators have benefitted from the Closed...
Read more -
ImageIntroducer sheath system with excellent kink resistance, easy insertion and superb radiopacity
Fortress®
Indicated to provide access into the femoral, popliteal and infrapopliteal arteries.*
Read more -
ImageYour Patient`s Companion
BIOTRONIK Patient App
With the BIOTRONIK Patient App, your patients can be involved in the management of their condition...
Read more -
ImageClinically proven stent with pull-back delivery system and 5.2F proximal shaft
Astron®
Indicated for use in patients with atherosclerotic disease of the iliac arteries and for the...
Read more -
ImageStent designed for flexibility and improved stent surface biocompatibility
Dynamic
Indicated for the treatment of de novo or restenotic atherosclerotic lesions in iliac arteries.*
Read more -
ImageOne Solution: Cross. Adjust. Restore.
Oscar®
The all-in-one solution to reach, cross and prepare lesions.1 One Solution: Multiple functions...
Read more -
ImageA dedicated renal artery stent with high flexibility and low crossing profile
Dynamic Renal
Indicated for improving arterial luminal diameter in patients with clinical symptoms attributable to...
Read more -
ImageMR Conditional Devices
ProMRI
For many years, patients with a pacemaker, ICD or CRT device, have been denied access to MRI. The...
Read more -
ImageDesigned for secure and efficient trapping
TrapIT
TrapIT trapping balloon catheter is designed to trap wires within guiding catheters securely for an...
Read more -
ImageNext-level Deliverability. Proven DES.
Orsiro®Mission
Orsiro Mission DES is indicated for improving coronary luminal diameter in patients with symptomatic...
Read more -
ImageAspiration Catheter
3Flow
Indicated for central and peripheral circulatory system including saphenous vein grafts.a
Read more -
ImageA unique solution for guide wire redirection and support
ReCross
The crossability of ReCross microcatheter is comparable to best in class antegrade single lumen...
Read more -
ImageClinically proven. Best in class crossability.
Pantera® Lux®
Pantera Lux Coronary Drug-Coated Balloon (DCB) is indicated for balloon dilatation for in-stent...
Read more -
ImageDesigned for reliable delivery of devices to target
Guidion Hydro
Guidion Hydro guide extension catheter has a radiopaque soft tip for true distal end visibility...
Read more -
ImageLow profile, puncture resistant balloon with enhanced crossability
Passeo®-35
Indicated to dilate stenosis in the renal, iliac1, femoral, popliteal and infrapopliteal arteries...
Read more -
ImageDesigned to advance dual guide wire procedures
NHancer Rx
With its rapid exchange (Rx) delivery lumen and the additional over the wire (OTW) lumen NHancer Rx...
Read more -
ImageDesigned to save lives when seconds count
PK Papyrus®
PK Papyrus covered coronary stent is indicated for acute coronary artery perforations.a Delivers...
Read more -
Image360°CRT
Evity 8 HF-T QP/HF-T
Evity 8 CRT pacemakers take CRT a step further than implantation and therapy, enabling unique...
Read more -
ImageQuadripolar MR conditional LV Lead
Sentus OTW QP
Sentus OTW QP is a family of left-ventricular (LV) quadripolar (QP) leads designed to be easily...
Read more -
ImageClinically proven thin struts stent with tri-axial delivery system
Pulsar®-35
Indicated for use in patients with atherosclerotic disease of the femoral and proximal popliteal...
Read more -
ImageLEAD DELIVERY SYSTEM
Selectra
BIOTRONIK has a long history of excellence in product design and performance and adheres to high...
Read more -
ImageQUALITY REDEFINED.
Renamic
The Renamic programmer is the result of intensive collaboration between BIOTRONIK engineers and...
Read more -
Image360°CRT
Enitra 8 HF-T QP/HF-T
Enitra 8 CRT pacemakers take CRT a step further than implantation and therapy, enabling unique...
Read more -
ImageThe Neo Connectivity
Renamic Neo
The Renamic Neo programmer offers complete connectivity and a long battery runtime to enable mobile...
Read more -
ImageCardiac Monitoring. Made Clearer.
BIOMONITOR III
Every year, more and more patients are receiving ICMs — all of which must be actively managed...
Read more -
ImageINTUITIVE DESIGN, COMPLETE RELIABILITY
Reocor
BIOTRONIK has an unsurpassed legacy of providing high-quality therapy solutions. We cultivate the...
Read more -
ImageCONTINUOUS CARE WITH MAXIMUM PATIENT COMFORT
CardioMessenger Smart
The mobile CardioMessenger Smart looks like a smartphone and can be used on the go for up to 48...
Read more -
Image360° CRT
Inlexa 3 HF-T QP/HF-T
BIOTRONIK CRT-D systems offer all the options needed for implantation and therapy optimization. Plus...
Read more -
ImagePERFECTING LIFELONG PROTECTION
Intica Neo 7 HF-T QP/HF-T
For more than 50 years, BIOTRONIK has consistently demonstrated innovation and excellent quality...
Read more -
ImageMR conditional ICD lead with Helix Design
Plexa
For BIOTRONIK, the status quo is never enough: as a company founded by engineering principles, we...
Read more -
ImagePERFECTING LIFELONG PROTECTION
Intica 5 VR-T/VR-T DX/DR-T
For several decades, BIOTRONIK has consistently demonstrated innovation and excellent quality within...
Read more -
Image360° CRT
Intica 5 HF-T QP/HF-T
BIOTRONIK CRT-D systems offer all the options needed for implantation and therapy optimization. Plus...
Read more -
Image360°CRT
Enticos 8 HF-T QP/HF-T
Enticos 8 CRT pacemakers take CRT a step further than implantation and therapy, enabling unique...
Read more -
Image360° CRT
Intica 7 HF-T QP/HF-T
BIOTRONIK CRT-D systems offer all the options needed for implantation and therapy optimization. Plus...
Read more -
ImagePERFECTING LIFELONG PROTECTION
Inlexa 3 VR-T/DR-T
For several decades, BIOTRONIK has consistently demonstrated innovation and excellent quality within...
Read more -
ImageClinically proven thin struts stent on a 4F profile
Pulsar®-18
Indicated for use in patients with atherosclerotic disease of the femoral and infrapopliteal...
Read more -
ImagePERFECTING LIFELONG PROTECTION
Intica Neo 5 HF-T QP/HF-T
For more than 50 years, BIOTRONIK has consistently demonstrated innovation and excellent quality...
Read more -
ImageLow profile PTA balloon with high pushability in a wide range of sizes
Passeo®-18
Passeo-18 is indicated to dilate stenosis in the femoral, popliteal and infrapopliteal arteries and...
Read more -
ImageA FAST DEFLATING PTA Balloon to treat long complex lower limb lesions
Passeo®-14
Indicated for balloon dilatation of the stenotic portion of a lower limb artery for the purpose of...
Read more -
ImagePERFECTING LIFELONG PROTECTION
Intica Neo 7 VR-T/VR-T DX/DR-T
For several decades, BIOTRONIK has consistently demonstrated innovation and excellent quality within...
Read more -
Image
Solia S, T/JT
Solia pacing leads comprise a complete portfolio of MR conditional active and passive pacing leads...
Read more -
ImagePERFECTING LIFELONG PROTECTION
Ilivia Neo 7 VR-T/VR-T DX/DR-T
For several decades, BIOTRONIK has consistently demonstrated innovation and excellent quality within...
Read more -
ImageMINIMAL SIZE. PROVEN SOLUTIONS
Enitra 6 DR-T/SR-T
Enitra 6 pacemakers combine small size with a complete suite of tools for comprehensive diagnostics...
Read more -
ImagePERFECTING LIFELONG PROTECTION
Intica Neo 5 VR-T/VR-T DX/DR-T
For several decades, BIOTRONIK has consistently demonstrated innovation and excellent quality within...
Read more -
ImageMore Life. Made Simpler.
Rivacor 7 VR-T / DR-T
Improving treatment and reducing risk for up to 15 years1
For patients with arrhythmias, ICD therapy...
Read more -
ImagePERFECTING LIFELONG PROTECTION
Intica 7 VR-T/VR-T DX/DR-T
For several decades, BIOTRONIK has consistently demonstrated innovation and excellent quality within...
Read more -
ImageMINIMAL SIZE. SOLID THERAPY.
Enticos 4 DR/D/SR/S
Enticos 4 pacemakers combine small size with a complete suite of tools for powerful bradycardia...
Read more -
ImageMINIMAL SIZE. MAXIMUM OPTIONS.
Enitra 8 DR-T/SR-T
Small, Enduring, Complete, Smart — Enitra 8 pacemakers combine small size with a complete suite of...
Read more -
ImageThe next generation iliac stent with excellent radial strength and superb flexibility
Dynetic®-35
With usable lengths up to 170cm, Dynetic-35 stent system allows a radial approach for the treatment...
Read more -
ImageUnique high-pressure PTA Balloon to dilate resistant lesions in complex anatomy
Passeo®-35 HP
Passeo-35 HP is a unique high pressure PTA Balloon to dilate most resistant lesions in complex...
Read more -
ImageMINIMAL SIZE. PROVEN SOLUTIONS.
Evity 6 DR-T/SR-T
Evity 6 pacemakers combine small size with a complete suite of tools for comprehensive diagnostics...
Read more -
ImageNon-Compliant High Pressure Balloon Catheter
Pantera®LEO
Indicated for stent post-dilatation and dilatation of a coronary artery or bypass graft stenosis.a
Read more -
ImageMINIMAL SIZE. MAXIMUM OPTIONS.
Evity 8 DR-T/SR-T
Small, Enduring, Complete, Smart — Evity 8 pacemakers combine small size with a complete suite of...
Read more -
ImageMore Life. Made Simpler.
Acticor 7 VR-T / DR-T
Improving treatment and reducing risk for up to 15 years1
For patients with arrhythmias, ICD...
Read more -
ImageNon-Invasive Hemostasis Device
Neptune® Pad
Indicated to promote the rapid control of bleeding and provide hemostasis at the skin surface.a
Read more -
ImageA unique combination of 3 technologies
Pulsar®-18 T3
Pulsar-18 T3 is the first clinically-proven thin strut stent mounted on a tri-axial low profile (4F)...
Read more -
ImageLow profile PTA balloon with excellent deliverability in a wide range of sizes
Passeo®-35 Xeo®
With usable lengths up to 170cm, Passeo-35 Xeo balloon allows a radial approach1 to dilate stenosis...
Read more -
Image4 mm Non-irrigated GoldTip Ablation catheter
AlCath G FullCircle
The AlCath G FullCircle catheter is availble in various curve sizes with FullCircle (> 180°)...
Read more -
Image3.5 mm irrigated tip Ablation catheter
AlCath Flux eXtra
The AlCath Flux eXtra irrigated ablation catheter has a special platinum iridium tip, FullCircle...
Read more -
ImageClinically proven results in challenging patient groups
Passeo®-18 Lux®
The Passeo-18 Lux Drug-Coated Balloon is indicated to dilate de novo or restenotic lesions in the...
Read more -
Image4 mm Non-irrigated Ablation Catheter
AlCath FullCircle
The AlCath FullCircle series of ablation catheters are available in different electrode tip lengths...
Read more -
ImageMaximised Precision. Minimised Workload.
BIOMONITOR IIIm
Physicians working with ICMs generally have a very heavy workload and false positive AF detections...
Read more -
Image8 mm Non-irrigated GoldTip Ablation catheter
AlCath LT G FullCircle
The AlCath LT G FullCircle catheter with its unique long GoldTip is availble in various curve sizes...
Read more -
Image3.5 mm irrigated GoldTip Ablation catheter
AlCath Flux G eXtra
The AlCath Flux G eXtra irrigated ablation catheter has a unique gold tip, FullCircle (> 180°)...
Read more -
Image8 mm Non-irrigated Ablation catheter
AlCath LT FullCircle
The AlCath LT FullCircle is availble in various curve sizes with FullCircle (> 180°) deflection...
Read more -
ImageADVANCED DIAGNOSTICS. OPTIMIZED CARE.
DX Technology
Atrial Fibrillation Management Solution for Single-Chamber ICD Patients
Atrial fibrillation (AF) is...
Read more -
ImageUniversal Heart Stimulator
Qubic Stim
BIOTRONIK’s cardiac stimulation device Qubic Stim represents the high quality in manufacturing...
Read more -
ImageIntracardiac Catheter for Temporary Cardiac Pacing
5F Bipolar Pacing Catheter™ w/o Balloon
Read more -
Image8 mm GoldTip Flutter Ablation catheter
AlCath Flutter LT G
Designed specifically for treating atrial flutter, this 95cm-long catheter is optimized for ablating...
Read more -
ImageAccurate Prediction. Proactive Care.
HeartInsight — Heart Failure Management Solution
Heart failure is a leading cause of hospitalizations, and each hospitalization reflects a...
Read more -
ImageIntracardiac Catheter for Temporary Cardiac Pacing
5F Bipolar Pacing Catheter™ with Balloon
Read more -
ImageReduce your exposure to scattered radiation
Texray
Personal radiation protection devices used to protect from harmful ionizing radiation are sometimes...
Read more -
ImageSteerable Diagnostic CAT
ViaCath
The catheters of the ViaCath family are steerable, multipolar diagnostic catheters for intracardiac...
Read more -
ImagePERFECTING LIFELONG PROTECTION
Ilivia Neo 7 HF-T QP/HF-T
For more than 50 years, BIOTRONIK has consistently demonstrated innovation and excellent quality...
Read more -
ImageHigh push. High cross coronary balloon.
Pantera® Pro
Indicated for dilatation of coronary artery or bypass graft stenosis.a
Read more -
Image360°CRT
Edora 8 HF-T QP/HF-T
Edora 8 CRT pacemakers take CRT a step further than implantation and therapy, enabling unique...
Read more -
ImageNon-Steerable Diagnostic Catheters
MultiCath
The catheters of the MultiCath family are pre-shaped, multipolar diagnostic catheters for...
Read more -
Image3.5 mm irrigated GoldTip Flutter Ablation catheter
AlCath Flutter Flux G eXtra
Designed specifically for treating atrial flutter, this 95cm-long catheter is optimized for ablating...
Read more -
ImageIrrigation Pump
Qiona
The Qiona irrigation pump is the perfect addition to the ablation setup. It features adjustable low...
Read more -
ImageMINIMAL SIZE. MAXIMUM OPTIONS.
Edora 8 DR-T/SR-T
Small, Enduring, Complete, Smart — Edora 8 pacemakers combine small size with a complete suite of...
Read more
Contact Us
References
1. Kapur et al., AI/machine learning AF algorithm improves clinical workflow in ICM. Presented at 16th Asia Pacific Heart Rhythm Society Scientific Session in Conjunction with CardioRhythm (APHRS 2023), 31 August - 3 September, Hong Kong; 2. Iwai et al., Novel automated overread strategy significantly improves clinical workflow in ICM remote monitoring. Presented at 16th Asia Pacific Heart Rhythm Society Scientific Session in Conjunction with CardioRhythm (APHRS 2023), 31 August - 3 September, Hong Kong; 3. SmartECG AF filtering programmed to Very Specific. Sensitivity and specificity depend on the programmed SmartECG filter configuration. Data on file 2023; 4. Bisignani et al., Implantable cardiac monitors: Artificial intelligence and signal processing reduce remote ECG review workload and preserve arrhythmia detection sensitivity. Frontiers in Cardiovascular Medicine. Volume 11 - 2024. doi: 10.3389/fcvm.2024.1343424; 5. Mariani JA, Weerasooriya R, van den Brink O, Mohamed U, Gould PA, Pathak RK, et al. Miniaturized implantable cardiac monitor with a long sensing vector (BIOMONITOR III): Insertion procedure assessment, sensing performance, and home monitoring transmission success. J Electrocardiol. 2020;60:118–25. doi: 10.1016/j.jelectrocard.2020.04.004; 6. Dukes et al., Novel PVC detection algorithm in an implantable cardiac monitor for longitudinal risk monitoring. Presented at ESC Congress 2023, August 25-27; Amsterdam, Netherlands; 7. Marmerstein, Joseph, et al. Evaluation of a Novel PVC and PAC Detection Algorithm in an Implantable Cardiac Monitor for Longitudinal Risk Monitoring. Hearty Rhythm O2, Aug. 2023; 8. Binici Z, Intzilakis T, Nielsen OW, Køber L, Sajadieh A. Excessive supraventricular ectopic activity and increased risk of atrial fibrillation and stroke. Circulation. 2010;121(17):1904–11. doi: 10.1161/CIRCULATIONAHA.109.874982; 9. Larsen BS, Kumarathurai P, Falkenberg J, Nielsen OW, Sajadieh A. Excessive Atrial Ectopy and Short Atrial Runs Increase the Risk of Stroke Beyond Incident Atrial Fibrillation. J Am Coll Cardiol. 2015;66(3):232–41. doi: 10.1016/j.jacc.2015.05.018; 10. Todo K, Iwata T, Doijiri R, Yamagami H, Morimoto M, Hashimoto T, et al. Frequent Premature Atrial Contractions in Cryptogenic Stroke Predict Atrial Fibrillation Detection with Insertable Cardiac Monitoring. Cerebrovasc Dis. 2020:1–7. doi: 10.1159/000505958. PubMed PMID: 32023609; 11. Dukes JW, Dewland TA, Vittinghoff E, Mandyam MC, Heckbert SR, Siscovick DS, et al. Ventricular Ectopy as a Predictor of Heart Failure and Death. J Am Coll Cardiol. 2015;66(2):101–9. doi: 10.1016/j.jacc.2015.04.062. 12. Mariani JA et al. J Electrocardiol. 2020, 60; 13. Deneke et al VOLUME 3, ISSUE 2, P152-159, APRIL 01, 2022, https://www.heartrhythmopen.com/article/S2666-5018(22)00044-7