AlCath Flux G eXtra
The AlCath Flux G eXtra irrigated ablation catheter has a unique gold tip, FullCircle (> 180°) deflection, and a three-dimensional cooling pattern, providing more effective therapy for supraventricular tachycardias.
Category
Product Highlights
eXtra Design
12 irrigation holes on 3 levels arranged with a 3D irrigation pattern
FullCircle Deflection
Deflectability beyond 180 degrees through FullCircle deflection
Irrigated GoldTip ablation
GoldTip ablation results in superior acute efficacy and shorter procedure times in treating atrial arrhythmias
Technical Data
Curve Type | Red, blue, green, black, cyan |
Electrode spacing | 2-5-2 mm |
Effective catheter length | 110 cm |
Shaft diameter | 7 F |
Curve shape | Steerable - FullCircle |
Tip electrode type | Irrigated |
Ordering Information
Model | Tip | Curve | Spacing | Shaft Diameter | Length | Order Number |
---|---|---|---|---|---|---|
AlCath Flux Red G eXtra | 3.5 mm irrigated | Red | 2-5-2 mm | 7 F | 110 cm | 376 379 |
AlCath Flux Blue G eXtra | 3.5 mm irrigated | Blue | 2-5-2 mm | 7 F | 110 cm | 376 388 |
AlCath Flux Green G eXtra | 3.5 mm irrigated | Green | 2-5-2 mm | 7 F | 110 cm | 376 384 |
AlCath Flux Black G eXtra | 3.5 mm irrigated | Black | 2-5-2 mm | 7 F | 110 cm | 376 390 |
AlCath Flux Cyan G eXtra | 3.5 mm irrigated | Cyan | 2-5-2 mm | 7 F | 110 cm | 376 386 |
Related Products
-
ImageGUIDE EXTENSION CATHETER designed to address CTO PCI
Guidion Short
Facilitate trapping of OTW devices with Guidion Short!1
Enable trapping techniques of OTW devices in...Read more -
ImageGUIDE EXTENSION CATHETER WITH PERFUSION HOLES TO MAINTAIN BLOOD FLOW* DURING DEEP INTUBATION
FlowGuide
Reduce the risk of pressure damping and procedure induced ischemia1. FlowGuide has 9 circumferential...
Read more -
ImageComplete system. Expert support.
BIOTRONIK Conduction System Pacing Solution
Working alongside physicians and listening closely to their needs, we have together developed a...
Read more -
ImageIntelligence. Confidence. Clarity
BIOMONITOR IV
A real challenge exists in the clinical world today with the volume of data generated as more...
Read more -
ImageReduce your exposure to scattered radiation
Texray
Personal radiation protection devices used to protect from harmful ionizing radiation are sometimes...
Read more -
ImageOptimized therapy. Simplified care.
Amvia Sky HF-T QP / HF-T
With a 30% non-response rate to CRT1 , therapy optimization is essential for clinicians taking care...
Read more -
ImageMetallic Performance¹⁻³. Fully Resorbable*⁴
Freesolveᵀᴹ
Indicated for de novo coronary artery lesionsa
Support
Resorbable coronary scaffolds widen coronary...Read more -
ImageTHE SUSPENDED RADIATION PROTECTION SYSTEM
Zero-Gravity®
The growing number and complexity of fluoroscopic procedures performed each year has increased the...
Read more -
ImageA dedicated renal artery stent with high flexibility and low crossing profile
Dynamic Renal
Indicated for improving arterial luminal diameter in patients with clinical symptoms attributable to...
Read more -
ImageMR Conditional Devices
ProMRI
For many years, patients with a pacemaker, ICD or CRT device, have been denied access to MRI. The...
Read more -
ImageIntroducer sheath system with excellent kink resistance, easy insertion and superb radiopacity
Fortress®
Indicated to provide access into the femoral, popliteal and infrapopliteal arteries.*
Read more -
ImageOne Solution: Cross. Adjust. Restore.
Oscar®
The all-in-one solution to reach, cross and prepare lesions.1 One Solution: Multiple functions...
Read more -
ImageExtending ICD Lead Choices
Pamira
Over the years, BIOTRONIK kept on innovating and improving ICD leads, having in mind long-term...
Read more -
ImageDesigned for reliable delivery of devices to target
Guidion Hydro
Guidion Hydro guide extension catheter has a radiopaque soft tip for true distal end visibility...
Read more -
ImageDesigned to save lives when seconds count
PK Papyrus®
PK Papyrus covered coronary stent is indicated for acute coronary artery perforations.a Delivers...
Read more -
ImageClinically proven stent with pull-back delivery system and 5.2F proximal shaft
Astron®
Indicated for use in patients with atherosclerotic disease of the iliac arteries and for the...
Read more -
ImageClinically proven. Best in class crossability.
Pantera® Lux®
Pantera Lux Coronary Drug-Coated Balloon (DCB) is indicated for balloon dilatation for in-stent...
Read more -
ImageEven better deliverability for the outstanding Orsiro DES
Orsiro®Mission
Orsiro Mission DES is indicated for improving coronary luminal diameter in patients with symptomatic...
Read more -
ImageAspiration Catheter
3Flow
Indicated for central and peripheral circulatory system including saphenous vein grafts.a
Read more -
ImageDesigned for secure and efficient trapping
TrapIT
TrapIT trapping balloon catheter is designed to trap wires within guiding catheters securely for an...
Read more -
ImageQuadripolar MR conditional LV Lead
Sentus OTW QP
Sentus OTW QP is a family of left-ventricular (LV) quadripolar (QP) leads designed to be easily...
Read more -
ImageThe Neo Connectivity
Renamic Neo
The Renamic Neo programmer offers complete connectivity and a long battery runtime to enable mobile...
Read more -
ImageINTUITIVE DESIGN, COMPLETE RELIABILITY
Reocor
BIOTRONIK has an unsurpassed legacy of providing high-quality therapy solutions. We cultivate the...
Read more -
ImageLEAD DELIVERY SYSTEM
Selectra
BIOTRONIK has a long history of excellence in product design and performance and adheres to high...
Read more -
ImageA unique solution for guide wire redirection and support
ReCross
The crossability of ReCross microcatheter is comparable to best in class antegrade single lumen...
Read more -
ImageDesigned to advance dual guide wire procedures
NHancer Rx
With its rapid exchange (Rx) delivery lumen and the additional over the wire (OTW) lumen NHancer Rx...
Read more -
ImageQUALITY REDEFINED.
Renamic
The Renamic programmer is the result of intensive collaboration between BIOTRONIK engineers and...
Read more -
ImageClinically proven thin struts stent with tri-axial delivery system
Pulsar®-35
Indicated for use in patients with atherosclerotic disease of the femoral and proximal popliteal...
Read more -
ImageMR conditional ICD lead with Helix Design
Plexa
For BIOTRONIK, the status quo is never enough: as a company founded by engineering principles, we...
Read more -
ImagePERFECTING LIFELONG PROTECTION
Ilivia Neo 7 VR-T/VR-T DX/DR-T
For several decades, BIOTRONIK has consistently demonstrated innovation and excellent quality within...
Read more -
Image
Solia S, T/JT
Solia pacing leads comprise a complete portfolio of MR conditional active and passive pacing leads...
Read more -
ImageA FAST DEFLATING PTA Balloon to treat long complex lower limb lesions
Passeo®-14
Indicated for balloon dilatation of the stenotic portion of a lower limb artery for the purpose of...
Read more -
ImageLow profile PTA balloon with high pushability in a wide range of sizes
Passeo®-18
Passeo-18 is indicated to dilate stenosis in the femoral, popliteal and infrapopliteal arteries and...
Read more -
ImageNon-Invasive Hemostasis Device
Neptune® Pad
Indicated to promote the rapid control of bleeding and provide hemostasis at the skin surface.a
Read more -
ImageThe next generation iliac stent with excellent radial strength and superb flexibility
Dynetic®-35
With usable lengths up to 170cm, Dynetic-35 stent system allows a radial approach for the treatment...
Read more -
ImageUnique high-pressure PTA Balloon to dilate resistant lesions in complex anatomy
Passeo®-35 HP
Passeo-35 HP is a unique high pressure PTA Balloon to dilate most resistant lesions in complex...
Read more -
ImageNon-Compliant High Pressure Balloon Catheter
Pantera®LEO
Indicated for stent post-dilatation and dilatation of a coronary artery or bypass graft stenosis.*
Read more -
Image4 mm Non-irrigated GoldTip Ablation catheter
AlCath G FullCircle
The AlCath G FullCircle catheter is availble in various curve sizes with FullCircle (> 180°)...
Read more -
ImageClinically proven results in challenging patient groups
Passeo®-18 Lux®
The Passeo-18 Lux Drug-Coated Balloon is indicated to dilate de novo or restenotic lesions in the...
Read more -
Image8 mm Non-irrigated GoldTip Ablation catheter
AlCath LT G FullCircle
The AlCath LT G FullCircle catheter with its unique long GoldTip is availble in various curve sizes...
Read more -
ImageA unique combination of 3 technologies
Pulsar®-18 T3
Pulsar-18 T3 is the first clinically-proven thin strut stent mounted on a tri-axial low profile (4F)...
Read more -
ImageMore Life. Made Simpler.
Acticor 7 VR-T / DR-T
Improving treatment and reducing risk for up to 15 years1
For patients with arrhythmias, ICD...
Read more -
ImageLow profile PTA balloon with excellent deliverability in a wide range of sizes
Passeo®-35 Xeo®
With usable lengths up to 170cm, Passeo-35 Xeo balloon allows a radial approach1 to dilate stenosis...
Read more -
Image8 mm GoldTip Flutter Ablation catheter
AlCath Flutter LT G
Designed specifically for treating atrial flutter, this 95cm-long catheter is optimized for ablating...
Read more -
ImageIntracardiac Catheter for Temporary Cardiac Pacing
5F Bipolar Pacing Catheter™ with Balloon
Read more -
ImageNon-Steerable Diagnostic Catheters
MultiCath
The catheters of the MultiCath family are pre-shaped, multipolar diagnostic catheters for...
Read more -
ImageIrrigation Pump
Qiona
The Qiona irrigation pump is the perfect addition to the ablation setup. It features adjustable low...
Read more -
ImageIntracardiac Catheter for Temporary Cardiac Pacing
5F Bipolar Pacing Catheter™ w/o Balloon
Read more -
Image3.5 mm irrigated GoldTip Flutter Ablation catheter
AlCath Flutter Flux G eXtra
Designed specifically for treating atrial flutter, this 95cm-long catheter is optimized for ablating...
Read more -
ImageUniversal Heart Stimulator
Qubic Stim
BIOTRONIK’s cardiac stimulation device Qubic Stim represents the high quality in manufacturing...
Read more -
ImageSteerable Diagnostic CAT
ViaCath
The catheters of the ViaCath family are steerable, multipolar diagnostic catheters for intracardiac...
Read more -
ImageMore Life. Made Simpler.
Acticor 7 HF-T QP/HF-T
Simplified and optimized CRT for up to 9 years1
Heart failure is tough to live with and can be...
Read more -
ImageHigh push. High cross coronary balloon.
Pantera® Pro
Indicated for dilatation of coronary artery or bypass graft stenosis.a
Read more -
ImagePERFECTING LIFELONG PROTECTION
Ilivia Neo 7 HF-T QP/HF-T
For more than 50 years, BIOTRONIK has consistently demonstrated innovation and excellent quality...
Read more -
ImageMINIMAL SIZE. MAXIMUM OPTIONS.
Edora 8 DR-T/SR-T
Small, Enduring, Complete, Smart — Edora 8 pacemakers combine small size with a complete suite of...
Read more -
Image360°CRT
Edora 8 HF-T QP/HF-T
Edora 8 CRT pacemakers take CRT a step further than implantation and therapy, enabling unique...
Read more -
ImagePhysiologic choices. Simplified workflows.
Amvia Sky DR-T/SR-T
The Amvia Sky pacing system gives you choices. Take advantage of a broader range of treatment...
Read more -
ImageAccurate Prediction. Proactive Care.
HeartInsight — Heart Failure Management Solution
Heart failure is a leading cause of hospitalizations, and each hospitalization reflects a...
Read more -
ImageYour Patient`s Companion
BIOTRONIK Patient App
With the BIOTRONIK Patient App, your patients can be involved in the management of their condition...
Read more -
ImageCONTINUOUS CARE WITH MAXIMUM PATIENT COMFORT
CardioMessenger Smart
The mobile CardioMessenger Smart looks like a smartphone and can be used on the go for up to 48...
Read more -
ImageSave Time. Improve Outcomes.
BIOTRONIK Home Monitoring
Taking care of cardiac device patients can be challenging. The BIOTRONIK remote monitoring system is...
Read more -
ImageMultiple solutions for lesion crossing
Carnelian® Support Catheter
A Support Microcatheter indicated for the exchange and support of guidewires into peripheral...
Read more