Guidion Hydro
Guidion Hydro guide extension catheter has a radiopaque soft tip for true distal end visibility facilitating precise device positioning. The high density coiling of the distal shaft ensures optimal lumen integrity and smooth device delivery. A proximal oval push rod design keeps the profile low while securing optimal pushability.1
Product Highlights
True distal end visibility¹
For precise device positioning
Flex Zoneᵃ and hydrophilic coating
For advanced trackability1
Coil reinforced shaft
For smooth device delivery1
Product Overview
Guidion Hydro
Radiopaque soft tip
Flex Zone
Coil reinforced shaft
Transition Zone
Oval push rod
Technical Data
Guide Extension Catheter | |
---|---|
Distal shaft length | 25 cm |
Shaft material | Polyether Block Amide |
Tip | Flexible, radiopaque, 1.3 mm length |
Outer coating | Hydrophilic distal 10 cm |
Exit markers | 95 cm and 105 cm |
Usable length | 150 cm |
Size and Compatibility
BIOTRONIK/IMDS Portfolio | ||||||||
---|---|---|---|---|---|---|---|---|
Navigate | Prepare | Treat | ||||||
Guidion Hydro | Recross2 | Nhancer Rx2 | Pantera LEO2 | Pantera Pro2 | Orsiro Mission2 | Pantera Lux2 | Freesolve3 | PK Papyrus2 |
5F | - | - | - | - | - | - | - | - |
6F | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | - | ✔(2.5-4.0) |
7F | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔(2.5-4.0) |
8F | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔(2.5-5.0) |
Other Devices | |||||||
---|---|---|---|---|---|---|---|
IVUS | Single Lumen Microcatheters | Rotablator Burr | IVL | ||||
Guidion Hydro | Eagle Eye Platinum Family, Refinity ST4 |
ACIST KODAMA3 |
Low Profile OD Microcatheters (<3F)5 |
Large Profile OD Microcatheters (>3F)5 |
1.25 mm6 & 1.5 mm6 |
Shockwave C27 |
Shockwave C2+8 |
5F | - | - | ✔ | - | - | - | ✔ |
6F | ✔ | - | ✔ | ✔ | - | ✔ | ✔ |
7F | ✔ | - | ✔ | ✔ | ✔ | ✔ | ✔ |
8F | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
Ordering Information
Ordering number | IMDS article number | Required guide catheter ID | Guidion Hydro ID |
---|---|---|---|
451663 | G50F25150 | 5F, ID ≥ 0.056" (1.42 mm) | 0.041" (1.04 mm) |
451664 | G60F25150 | 6F, ID ≥ 0.070" (1.78 mm) | 0.056" (1.42 mm) |
451665 | G70F25150 | 7F, ID ≥ 0.078" (1.98 mm) | 0.062" (1.57 mm) |
451666 | G80F25150 | 8F, ID ≥ 0.088" (2.24 mm) | 0.071" (1.80 mm) |
Downloads and Related Links
Downloads
Related Links
How can we help you?
References
The compatibility conclusions provided in this document are based on general & public information. It is advised to consult the manufacturer of each device for precise compatibility details.
IVUS = Intravascular Ultrasound; IVL = Intravascular Lithotripsy
a. 6&7F. 1. IMDS data on file. 2. According to the comparison between minimum dimension of Guiding catheter of the device in the IFU and the labeled inner diameter of Guidion Hydro. 3. According to IFU. 4. According to the comparison between the requirement for Guiding Catheters (≥0.056"/ 1.42mm – Eagle Eye Platinum, Refinity ST and Eagle Eye Platinum ST, Philips IVUS Spec sheet Feb 2024) and the labeled inner diameter of Guidion Hydro. 5. Garbo R. et al. JACC Cardiovasc Interv. 2023 Aug 14;16(15):1833-1844. doi: 10.1016/j.jcin.2023.05.019. PMID: 37587590. 6. Pawłowski T. et al. Postepy Kardiol Interwencyjnej. 2021 Jun;17(2):210-213. doi: 10.5114/aic.2021.107502. Epub 2021 Jul 9. PMID: 34400924; PMCID: PMC8356840. 7. Based on C2 - PN 62185 Rev F - Shockwave C2 Coronary IVL Catheter IFU, US.pdf downloaded on Feb 7, 2024. 8. Based on PN 64192 Rev C – IFU, Shockwave C2+ Coronary IVL Catheter, US.pdf downloaded on Feb 7, 2024.
Freesolve, Lux, Orsiro, Orsiro Mission, Pantera and PK Papyrus are trademarks or registered trademarks of the BIOTRONIK Group of Companies. Guidion, NHancer Rx and ReCross are trademarks of IMDS. Manufactured by IMDS and distributed by BIOTRONIK in selected countries. All other trademarks are the property of their respective owner.