Stent designed for flexibility and improved stent surface biocompatibility

Indicated for the treatment of de novo or restenotic atherosclerotic lesions in iliac arteries.*

Catégorie

Vascular Intervention Peripheral Stent Systems

Product Highlights

Image

Excellent trackability

Image

Stent designed for flexibility in iliac arteries

Image

Improved stent surface biocompatibility

Excellent trackability

The Dynamic delivery system offers great trackability compared to competitive balloon expandable devices.1

Stent designed for flexibility in iliac arteries

The helical stent design provides optimal flexibility respecting vessel movement while the peak-to-valley design avoids any fish-scaling effects and optimizes stent scaffolding.

Improved stent surface biocompatibility²

The proBIO® silicon carbide coating acts as a barrier between the metal stent and the surrounding tissue and blood, protecting the surface of the stent. By providing a barrier against ion release, the coating creates a surface that reduces platelet aggregation while facilitating endothelialization.²

Technical Data

Stent  
Stent Balloon-expandable
Stent material Stainless Steel
Strut thickness 160 µm (ø 5.0 - 8.0 mm)

180 µm (ø 9.0 - 10.0 mm)
Shortening Negligible
Stent coating proBIO® (Amorphous Silicon Carbide)
Sizes ø 5.0 - 10.0 mm; L: 15 - 25 - 38 - 56 mm
Delivery system  
Catheter type OTW
Recommended guide wire 0.035”
Tip Soft, short, tapered, colored
Balloon markers 2 swaged markers
Shaft 5F, hydrophobic coating, dual-lumen
Usable length 80 cm and 130 cm (ø 5.0 - 8.0 mm)
Markers 2 swaged markers
Guide wire lumen Hydrophobic coating
Nominal Pressure (NP) 9 atm
Rated Burst Pressure (RBP) 15 atm (ø 5.0 - 8.0 mm)

13 atm (ø 9.0 - 10.0 mm)

 

Ordering Information

  Stent

ø (mm)
Catheter length 80 cm

Stent length (mm)
    15 25 38 56
  5.0 350110(5F) 350114(5F) 350120(6F) 350126(6F)
6F 6.0 350111 350115 350121 350127
7.0 350112 350116 350122 350128
8.0 350113 350117 350123 350129
9.0 - 350118 350124 350130
7F 10.0 - 350119 350125 350131
  Stent

ø (mm)
Catheter length 130 cm

Stent length (mm)
    15 25 38 56
  5.0 350132(5F) 350136(5F) 350140(6F) 350144(6F)
6F 6.0 350133 350137 350141 350145
7.0 350134 350138 350142 350146
8.0 350135 350139 350143 350147

 

How can we help you?

Je préfère être contacté par

*Votre question ou commentaire

References

*Indication as per IFU. Australia: not TGA approved for use within common iliac arteries.

1. BIOTRONIK data on file; 2. Rzany A, Schaldach M. Smart Material Silicon Carbide: Reduced Activation of Cells and Proteins on a-SiC:H-coated Stainless Steel. Progress in Biomedical Research 2001; May: 182- 194. 

Dynamic and proBIO are trademarks or registered trademarks of the BIOTRONIK Group of Companies. All other trademarks are the property of their respective owners.