Skip to main content
  • Image
    Rivacor 7 DR-T

Rivacor 7 DR-T

Incorporating more diagnostic and therapeutic capabilities into smaller devices 

The Ultraslim BIOshape eases implantation,1 features a thinner form factor and a more rounded, elliptical design for reduced skin pressure. Rivacor ICDs are the smallest, slimmest ICDs approved for 3T full-body MRI scans.2 They have an extended battery life of nearly 14 years,3 supported by extended warranties, to deliver the best patient care.
 

Category

ICD Tachycardia

Product Highlights

Image
Ultraslim

Ultraslim ICD

More rounded to reduce skin pressure and a more compact shape to reduce pocket size. 

Image
Longevity

Extended Longevity and Warranty

Extended battery life of nearly 14 years3 supported by a full 8-year warranty.*

Image

CLS

The market's only myocardial contractility measurement

Ultraslim ICD

Rivacor ICDs are small and slim — only 10mm from front to back — with a smooth, elliptical, and body-friendly BIOshape.4

  • The Ultraslim BIOshape eases implantation,5 features a thinner form factor and a more rounded, elliptical design for reduced skin pressure.
  • Over 90% of implanting physicians rated 'patient comfort' as 'better' or even 'much better' in comparison to previous models.6

Extended Longevity and Warranty

Extended battery life of nearly 14 years3 supported by a full 8-year warranty.*

Longevity estimates include daily Home Monitoring® transmissions.

CLS

Closed Loop Stimulation (CLS) continuously translates variations in myocardial contractility into physiologic pacing rate changes to appropriately support metabolic demands.

  1. Primary Sensor7: Takes measurements directly from myocardial tissue
  2. Built On A Beat-To-Beat Architecture8: Rapidly evaluates every beat, and is able to respond on the next beat
  3. Automated With Machine Learning8: Learns the patient while automatically recalibrating to systemic variations (changes in medication, hydration, etc.)

Contact Us

I prefer to be contacted by
*Fields are mandatory.

References

1. Post-market observation; interim-analysis, December 21, 2018. Data on file.

2. As part of an MR conditional system.

3. Rivacor DR-T 13.45 years: A,RV: 2.0 V/0.4 ms, 60 bpm; A: 500 Ω, RV: 700 Ω; A,RV: 15% pacing; 2 max. energy shocks/year; Home Monitoring: ON (daily transmission); Diagnostics: OFF

4. Contoured housing; Rivacor 7 DR-T: 60x66.5x10mm; 32ccm 

5. Post-market observation; interim-analysis, December 21, 2018. Data on file.

6. Post-Market observation; Final report, March, 2019. Data on file.

7. Malinowski et al. PACE. 1998, 21(11).

8. Zecchi P et al. Prog Biomed Res. 2000, 5(2).  

*Acticor 7 VR-T DX and Rivacor 7 VR-T– 10 years Rivacor 7 DR-T – 8 years Acticor 7 HF-T and Rivacor 7 HF-T – 6 years, please see warranty documentation available at https://manuals.biotronik.com/ for full terms and conditions.