Skip to main content
  • Image

Astron®

Clinically proven stent with pull-back delivery system and 5.2F proximal shaft

Indicated for improving luminal diameter in patients with iliac atherosclerotic lesions in vessel reference diameters between 4.3 mm and 9.5 mm and lesion lengths up to 105 mm. 

Category

Vascular Intervention Peripheral PVI Balloon Catheters

Product Highlights

Image

Clinically proven stent for the treatment of iliac disease

Image

Pull-back delivery system for simple stent deployment

Image

5.2F proximal shaft for contrast injection with device in sheath

Clinically proven stent for the treatment of iliac disease¹

Designed to provide suficient chronic outward force and flexibility

Segmented stent design and strut thickness to provide sufficient chronic outward force in the iliac territory, while the peak-to-valley design and S-articulating connecting bars provide multi-directional flexibility and avoid fish-scaling in tortuous arteries

proBIO® silicon carbide coating reduces ion release by acting as an effective and reliable barrier to nickel and other heavy metal ion diffusion2

Pull-back delivery system for simple stent deployment

Pull-back delivery system enables simple stent deployment, while the easy release relieves friction of introducer valve on the retractable shaft during stent deployment, providing a smoother action

5.2F proximal shaft for contrast injection with device in sheath³

6F distal shaft with a 5.2F proximal shaft allows contrast injection while the device is positioned inside the introducer and across the lesion

Technical Data

Stent  
Catheter type OTW
Recommended guidewire 0.035”
Stent material Nitinol
Strut thickness 225 μm (ø 10 mm = 230 μm)
Stent coating proBIO® (Amorphous Silicon Carbide)
Stent markers 4 gold markers each end
Sizes ø 7 - 10 mm; L: 30 - 80 mm
Proximal shaft 5.2F, hydrophobic coating
Usable length 72 and 130 cm

Ordering Information

 

  Stent
ø (mm)
Catheter length 72 cm
Stent length (mm)
     
    30 40 60 80
6F 7.0 364645 364646 364647 364648
8.0 364649 364650 364651 364652
9.0 364653 364654 364655 364656
10.0   364657 364658 364659

 

  Stent
ø (mm)
Catheter length 130 cm
Stent length (mm)
     
6F   30 40 60 80
7.0 343785 343786 343787 343788
8.0 343789 343790 343791 343792
9.0 343793 343794 343795 343796

 

How can we help you?

I prefer to be contacted by
*Fields are mandatory.

References

1. Burket MW, Brodmann M, Metzger C, Tan K, Jaff MR. Twelve-Month Results of the Nitinol Astron Stent in Iliac Artery Lesions. J Vasc Interv Radiol. 2016;27(11):1650-1656; 2. Nickel release test result: Schmehl JM, Harder C, Wendel HP, Claussen CD, Tepe G. Silicon carbide coating of nitinol stents to increase antithrombogenic properties and reduce nickel release. Cardiovasc Revasc Med. 2008 Oct-Dec;9(4):255-62; 3. BIOTRONIK Data on file.

* Indication as per IFU. Astron and proBIO are trademarks or registered trademarks of the BIOTRONIK Group of Companies.